Power Generation
5 MW – 60 MW
Power Generation
Supplying critical overhauling services and OEM-compatible spares to thermal power plants operating steam turbines from 5 MW to 60 MW. Our ex-OEM engineers ensure maximum plant availability.
Key Applications & Products
- Steam turbine major and minor overhauling
- Turbine erection and commissioning
- Lube oil system flushing per ISO 4406:99
- Rotor dynamic balancing and alignment
- Emergency stop valve manufacturing
- Filter elements and strainers supply
- HVAC pleated panel filters for control rooms & turbine halls
3 MW BHEL rotor vibration dropped from 9.2 to 0.8 mm/s after dynamic balancing. 26 months — zero bearing changes.
— Captive Power Plant, Telangana